Start voltage
Volt Partenza
V démarr.
Startspannung
A value of 255 corresponds to 100%
Motor PWM Period
Periodo PWM (Frequenza pilotaggio Motore)
52.2mS to 5.12 ms
Packet Timeout Value
Consist Address Active For F1
Consist Address Active For F2
Consist Address Active For F3
Consist Address Active For F4
Consist Address Active For F5
Consist Address Active For F6
Consist Address Active For F7
Consist Address Active For F8
Consist Address Active For FL in Forward
Consist Address Active For FL in Reverse
Consist Acceleration Rate
Additional consist acceleration (combined with CV3)
Consist Acceleration Sign
Consist Braking Rate
Additional consist braking (combined with CV4)
Consist Braking Sign
no table
no table
Straight Line
Log Curve 1
Log Curve 2
Log Curve 3
Log Curve 4
Log Curve 5
Log Curve 6
Log Curve 7
Exp Curve 1
Exp Curve 2
Exp Curve 3
Exp Curve 4
Exp Curve 5
Exp Curve 6
User Table
Speed Table Selection
System Normal
CV112-128 mapped to 49-65
CV Address Extension
System Normal
Data corrupted. Reset to defaults.
EEROM Data Corrupted
System Normal
Ignore Group3 steerage bit
Function Group 3 Disable
NMRA function map
Soundtraxx function map
Alternate Function Map
System Normal
Watchdog timeout occurred
Watchdog Timer Reset
System Normal
Checksum Test Failed
Program Checksum Failure
System Normal
No ACK from I2C bus
I2C Bus Acknowledge Failure
FL(f) controls headlight
FL(f) controls backup light
FL(f) controls output Horn
FL(f) controls output Bell
FL(f) controls FX1
FL(f) controls FX2
FL(f) controls output DynBrake
FL(r) controls headlight
FL(r) controls backup light
FL(r) controls output Horn
FL(r) controls output Bell
FL(r) controls FX1
FL(r) controls FX2
FL(r) controls output DynBrake
F1 controls headlight
F1 controls backup light
F1 controls output Horn
F1 controls output Bell
F1 controls FX1
F1 controls FX2
F1 controls output DynBrake
F2 controls headlight
F2 controls backup light
F2 controls output Horn
F2 controls output Bell
F2 controls FX1
F2 controls FX2
F2 controls output DynBrake
F3 controls output Bell
F3 controls FX1
F3 controls FX2
F3 controls output DynBrake
F3 controls output RPM+
F3 controls output RPM-
F3 controls output Dim
F4 controls output Bell
F4 controls FX1
F4 controls FX2
F4 controls output DynBrake
F4 controls output RPM+
F4 controls output RPM-
F4 controls output Dim
F5 controls output Bell
F5 controls FX1
F5 controls FX2
F5 controls output DynBrake
F5 controls output RPM+
F5 controls output RPM-
F5 controls output Dim
F6 controls output Bell
F6 controls FX1
F6 controls FX2
F6 controls output DynBrake
F6 controls output RPM+
F6 controls output RPM-
F6 controls output Dim
F7 controls output DynBrake
F7 controls output RPM+
F7 controls output RPM-
F7 controls output Dim
F7 controls output Mute
F8 controls output DynBrake
F8 controls output RPM+
F8 controls output RPM-
F8 controls output Dim
F8 controls output Mute
On/Off
Dimmable
Forward light F0F effect generated
directional
Rule 17 enable
Forward light F0F behavior
On/Off
Dimmable
Reverse light F0R effect generated
directional
Rule 17 enable
Reverse light F0R behavior
Hyperlight flash rate
0 is fast, 15 is slow, 4 is recommended for start
Grade crossing logic hold time
0-15 seconds
On at power up
On when loco selected
Startup Mode
Dynamic Digital Exhaust
Single Chime
Three Chime
Five Chime
Horn Select
Engine RPM Interlock
Bell Rate
low values = fast, high values = slow
Exhaust Auto Notching Control
Number of speed steps per throttle notch.
Airhorn Volume
Bell Volume
Exhaust Volume
Dynamic Brake Volume
Reset delle CV ai valori di fabbrica
Soundtraxx