familyname=Stationary Decoder manufacturer=Team Digital, LLC definitionSource=JMRI CV=1,"Servo Address" CV=2,"On Time CV value" CV=3,"Servo 1 Move Range" CV=5,"Relay Address" CV=7,","None","","Restart the Servette","","Move servos to center position","","Move servos back and forth","","Move servos to one end","","Move servos to the other end",""Test State" CV=7,"Version ID" CV=8,"Manufacturer ID" CV=10,"Servo 1 Center Position" CV=11,"Servo 2 Center Position" CV=12,"Route 1 Address" CV=14,"Route 2 Address" CV=16,"Route 3 Address" CV=18,"Route 4 Address" CV=20,"Route 5 Address" CV=22,"Route 6 Address" CV=24,"Route 7 Address" CV=26,"Route 8 Address" CV=29,","Mode 1 - Servo 2 Pos, output 2 has unique address","","Mode 2 - Servo 2 Pos, output 2 has servo address","","Mode 3 - Servo 3 Pos, output 2 has unique address","","Not used -do not select","","Mode 4 - Inputs control servo, output 2 has unique address",""Mode" CV=29,"Option 1" CV=29,"Option 2" CV=29,"Option 3" CV=31,"Ops Mode Address" CV=33,","b","3","t","1","c","2"" CV=34,","t","1","c","2"" CV=36,","Input Disabled","","On Low to High Transition","","On High to Low Transition","","On Change Transition",""Transition" CV=36,"Output Number" CV=36,","Close","0","Throw","2","Toggle","1" Output State" CV=44,","Input Disabled","","On Low to High Transition","","On High to Low Transition","","On Change Transition",""Transition" CV=44,"Output Number" CV=44,","Close","0","Throw","2","Toggle","1" Output State" CV=67,"Servo Move Speed" CV=71,","None","0","Sequence or rotate","1","Speed to Position","2"Servo Behavior" CV=71,"Reverse" CV=75,","None","","Will flash when servo is in the cw position","","Will flash when servo is in the ccw position",""Relay" Basic------ Servette Output Addresses ------ Use this number to set the address numberof the device the output is connected to.------ Special Functions ------ This is the same as a Loco address------ Notes: ------ The Custom Programmer format is recommendedMfg---- Sets the Servette to a particular test state - Use to help adjust servos ---- Only works in Ops mode Changes the value of CV7 (Version ID) as displayed in DP Test State may change when Version ID is readInputs------ Primary Input Control 1 ------ ------ Secondary Input Control 1 ------ Outputs---- Servo Configuration -------- Output Flashing -------- Sets the output state to always be the same at power on ---- Only applies if Option 1 is selectedServette Both Throw CloseRelay Throw CloseRoutes---- Remote Control Route Address ----CVs